Direkt zum Hauptinhalt

hpssacli Befehle

Verwendung des ssacli Tools

CommandKurze shortund andlange longNamen namesder Befehle

All

Alle commandsBefehle havehaben aeinen shortkurzen nameNamen, toum reducedie theLänge lengthder ofgesamten theEingabe totalan input provided to thedas ssacli Tool tool.zu Youreduzieren. canDu usekannst shortkurze oroder longlange name.Namen Hereverwenden. isHier aist listeine ofListe allaller commandsBefehle andund theirihrer longlangen andund shortkurzen names:Namen:

  • chassisname = ch
  • controller = ctrl
  • logicaldrive = ld
  • physicaldrive = pd
  • drivewritecache = dwc
  • licensekey = lk

YouDu cankannst specifyDsken disksauch alsofolgendermaßen as:angeben:

  • AEine rangeReihe ofvon drivesDisken (bay 1 to 3): 1I:1:1-1I:1:3
  • DrivesLaufwerke, thatdie arenicht unassigned:zugewiesen sind: allunassigned


ssacli pathPfade

/opt/hp/hpssacli/bin/hpssacli

/opt/smartstorageadmin/ssacli/bin/ssacli

HP Smart array CLI commands


Show configuration

/opt/hp/hpssacli/bin/hpssacli ctrl all show config
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show config

Controller status

/opt/hp/hpssacli/bin/hpssacli ctrl all show status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show status

Show detailed controller information for all controllers

/opt/hp/hpssacli/bin/hpssacli ctrl all show detail
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl all show detail

Show detailed controller information for controller in slot 0

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 show detail
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 show detail

Rescan for New Devices

/opt/hp/hpssacli/bin/hpssacli rescan
/opt/smartstorageadmin/ssacli/bin/ssacli rescan

Physical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show status

Show detailed physical disk information

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd all show detail
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd all show detail

Logical disk status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld all show status
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld all show status

View Detailed Logical Drive Status

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 show
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 show

Create New RAID 0 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0

Create New RAID 1 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1

Create New RAID 5 Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5

Delete Logical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 delete
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 delete

Add New Physical Drive to Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 add drives=2I:1:6,2I:1:7

Add Spare Disks

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array all add spares=2I:1:6,2I:1:7

Enable Drive Write Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=enable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=enable

Disable Drive Write Cache

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify dwc=disable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify dwc=disable

Erase Physical Drive

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 pd 2I:1:6 modify erase
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 pd 2I:1:6 modify erase
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=on
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=on
/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 ld 2 modify led=off
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 ld 2 modify led=off

Modify smart array cache read and write ratio (cacheratio=readratio/writeratio)

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify cacheratio=100/0
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify cacheratio=100/0

Enable smart array write cache when no battery is present (No-Battery Write Cache option)

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 modify nbwc=enable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 modify nbwc=enable

Disable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=disable

Enable smart array cache for certain Logical Volume

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 logicaldrive 1 modify arrayaccelerator=enable

Enable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=enable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=enable

Disable SSD Smart Path

/opt/hp/hpssacli/bin/hpssacli ctrl slot=0 array a modify ssdsmartpath=disable
/opt/smartstorageadmin/ssacli/bin/ssacli ctrl slot=0 array a modify ssdsmartpath=disable